THE WORLD LEADER IN CLEAN AIR SOLUTIONS PGH209 MEGAcel II High efficiency panel filter Features Specifications Application Product Parameter Compared with the traditional glass fiber filter, the energy saving effect is obvious Strong corrosion resistance, not easy to be damaged by acid, alkali, organic matter, can adapt to harsh use environment The low volatilization of chemical gas has almost no harm to the production process and personnel's health Filter material grade strength is higher, in the process of transportation and installation filter is not easy to damage Having a low total cost of ownership (TCO) helps customers save money Can meet the challenges of PAO testing, long service life It is widely used in all kinds of clean rooms, especially in the life science industry where frequent disinfection and PAO leak detection tests are required, and biosafety cabinets Model MII.H13-305x610x69-A1-PU11-PG11-M5-G-N0 MII.H13-610x610x69-A1-PU11-PG11-M5-G-N0 MII.H13-610x915x69-A1-PU11-PG11-M5-G-N0 MII.H13-610x1220x69-A1-PU11-PG11-M5-G-N0 MII.H13-570x570x69-A1-PU11-PG11-M5-G-N0 MII.H13-570x870x69-A1-PU11-PG11-M5-G-N0 Width (mm) Height (mm) Depth (mm) Airflow (m³/h) Pressure (pa) Efficiency EN1822 Volume (m³) 305 610 610 610 570 570 610 610 915 1220 570 870 69 69 69 69 69 69 258 545 832 1118 472 735 55 55 55 55 55 55 H13 H13 H13 H13 H13 H13 0.02 0.03 0.04 0.06 0.03 0.04 Frame: aluminum profile Filtering material: MEGAcel eFRM Filter material separator: hot melt Gasket: PU/EPDM Efficiency: EN1822 H13~H14 Fire protection rating: UL900 (Optional) Operating temperature: ≤70 Recommended final resistance: ≤500Pa
RkJQdWJsaXNoZXIy MjgzNzA=