CONSTRUCTION TECHNICAL SPECIFICATIONS Temperature Control Temperature range Temperature measurement Temperature Control Temperature Precisión Temperature Uniformity Temperature recovery Over Temperature Protection CO2 Sensor CO2 Range CO2 Range Uniformity Accuracy Recovery rate RELATIVE HUMIDITY SYSTEM Reservoir RH level DECONTAMINATION CYCLE Decontamination cycle type Temperature ramp up time Exposure time Temperature ramp down time Total cycle time Direct heat, 6 sides, 4 independently controlled heaters, 73 meters of heating elements 10-50° C in 0.1 increments ( minimum setting: ambient + 1° C) Seven RT curve matched thermistors +/- 0,1°C +/- 0,1°C Better than ± 0.3° C About 5 minutes following a 15 seconds door opening Independent, inhibits all heaters above 1.0° C over set temp. value (in the unlikely event of a control system failure) Solid State IR Sensor, automatic atmospheric CO2 zeroing. Measurement is independent from chamber humidity level 0.5 to 20 % CO2, in steps of 0.1% +/- 0,1% Better than ± 0.1 % CO2 ± 0.2% at 5% CO2 set point About 5 minutes following a 15 seconds door opening 2.5 litres, 304 Stainless Steel electro-polished humidity tray Minimum 95% Fully automatic, 125° C cycle, Validated 1,5- 2,5 hours 4 hours 5-7 hours 10,5 - 13,5 hours Inner Chamber Chamber volume (gross /usable) Internal Dimensions (W x H x D) mm External Dimensions (W x H x D) mm Exterior Interior access Door swing Net Weight Packed Weight SHELVING SYSTEM Shelf racks Shelf type Shelf dimensions (W x D) mm Shelf surface area, Sq meter Capacity: standard - maximum ALARM SYSTEM Chamber status alarm Incubator function alarm Alarm events Log POWER REQUIREMENTS Voltage Rated Power Power to maintain 37ºC EXTERNAL CONNECTIONS RS 232 output RS 232 interface Contact for remote alarm 304 Stainless Steel, totally seamless, electropolished 188.6 litres/140 litres 530 x 690 x 500 680 x 896 x 746 Powder painted mild steel with ABS plastic outer door cover Heated outer door with direct chamber access or sealed inner glass door (with optional 4/8 inner glass doors) Right side opening with optional left side door swing ( factory fitted) 102 Kg 135 Kg Easy to assemble , 304 stainless steel construction, with high temperature plastic spacerss Solid (non perforated) stainless steel shelves ( perforated available as option) 510x 455 mm, with 150 mm height above each shelf 0,23 m2 4-8 shelves Fully programmable, audio-visual, auto reset when chamber conditions resume Fully automatic alarms to advise failure in heaters or sensors Up to 500 alarm events held in memory on a rolling basis, displayed on 2 x 24 display, showing programmed value, actual value, time and duration of alarm event 220-240 V - 50-60 Hz 1,5 kW < 0,1 kW Operating conditions, alarms and events data output Standard supply, for remote access Volt-free. Remote external alarm device or alarm system (BMS) SIZES (mm) SIZES (mm) 1062 1958 Stacking system with castors www.cruma.es export@cruma.es
RkJQdWJsaXNoZXIy MjgzNzA=