קטלוג מוצרים ULPA - SUTO

2/4 Benefits Accurate saturated steam measurement by instant flow and consumption monitoring Integrated temperature sensor and small pressure loss High protection level due to robust industrial design and no moving parts Analog and Modbus output for data logging and analysis Wafer type makes it easy for installation S435 Vortex Flow Meter for Steam Vortex Flow Meter dimension rated pressure 1.6 MPa unit: mm DN A B C D 40 100 50 256 75 50 110 55 256 87 65 110 55 262 109 80 110 55 267 120 100 120 60 271 149 125 133 73 291 175 150 160 90 304 203 200 185 115 331 259 250 210 140 357 312 300 240 165 383 363 Vortex flow meters are the ideal choice for steam measurements due to their robust design, without any moving parts and high temperature/pressure resistance. S435 provides mass flow and consumption measurements in saturated steam with automatic density compensation. This always guarantees accurate results. Parameter settings can be done through the user interface (keys and display) at the flow meter directly. Connection to an SCADA system is through the Modbus/RTU interface or the analog output available. Please ensure that the steam parameters such as temperature, pressure and nominal flow are within the specification of S435. Use double bolts and nuts. We provide gaskets and bolts. Mating flanges Wafer type vortex flowmeter Installation studs, nuts and gaskets Graphite gasket Flow direction Installation 63mm 63mm C A Ø D B 31mm 70mm 80mm Ø92mm 12mm Accurate Steam Monitoring Dimensions

RkJQdWJsaXNoZXIy MjgzNzA=