קטלוג מוצרים ULPA - SUTO

www.suto-itec.com sales@suto-itec.com S450 / S452 Flow and Consumption Meter International Edition (EN) - 23-1. © 2023 SUTO iTEC GmbH. www.suto-itec.com Ordering Please use the following tables to assist in placing your order with our sales staff. S450 Thermal Mass Flow Meter (Insertion type) Order No. Description S695 0450 S450, Thermal Mass Flow Meter insertion type Shaft length A1200 220 mm A1201 160 mm A1202 300 mm Process connection A1006 PT 1/2” Adapter A1005 NPT 1/2” Adapter Gas type A1007 Air A1008 CO₂ A1009 O₂ (Oil- & grease-free cleaned) A1010 N₂ A1011 N₂O A1012 Argon A1013 Natural Gas A1014 H2 (real gas calibration) A1015 Other gas (please specify) A1016 He (real gas calibration) A1017 C₃H₈ A1041 O₂, Ar, CO₂ (real gas calibration) Range A1275 Standard A1271 Max range A1272 Bi-directional standard range A1273 Bi-directional max. range A1274 High speed A1276 Low range version (1/3 of standard range) Hazardous area approval A1279 None A1280 IECEx / GB3836 Ex Output A1284 2 x 4 ... 20 mA + pulse A1285 1 x 4 ... 20 mA + HART + pulse A1286 1 x 4 ... 20 mA + Modbus + pulse Display A1294 Without display A1295 With display Accessories Order No. Description R200 0005 Oil- & grease-free cleaned option for flow sensors (for Oxygen it is already included in A 1009) A530 1106 High pressure installation device S450, 220 mm (to be used if pressure above 1.5 MPa) A530 1113 High pressure installation device S450, 400 mm (to be used if pressure above 1.5 MPa) S452 Thermal Mass Flow Meter (In-line type) Order No. Description S695 0452 S452, Thermal Mass Flow Meter, inline type Process connection * A130X R-thread (ISO 7-1) A132X Flange EN 1092-1, PN40 A134X Flange ANSI 16.5 Measuring section size * 1 DN15 (1/2”) 2 DN20 (3/4”) 3 DN25 (1”) 4 DN32 (1.25”) 5 DN40 (1.5”) 6 DN50 (2”) 7 DN65 (2.5”) 8 DN80 (3”) Gas type A1007 Air A1008 CO₂ A1009 O₂ (Oil- & grease-free cleaned) A1010 N₂ A1011 N₂O A1012 Argon A1013 Natural Gas A1014 H₂ (real gas calibration) A1015 Other gas (please specify) A1016 He (real gas calibration) A1017 C₃H₈ A1041 O₂, Ar, CO₂ (real gas calibration) Range A1275 Standard A1271 Max range A1274 High speed (DN15 ... DN50) A1276 Low range version (1/3 of standard range) Hazardous area approval A1279 None A1280 IECEx / GB3836 Ex Output A1284 2 x 4 ... 20 mA + pulse A1285 1 x 4 ... 20 mA + HART + pulse A1286 1 x 4 ... 20 mA + Modbus + pulse Display A1294 Without display A1295 With display Attention: * Measuring section connection and size must be combined to get the order number. Example: A1306 = R-thread DN50

RkJQdWJsaXNoZXIy MjgzNzA=