קטלוג מוצרים ULPA - SUTO

15/16 Be smart. Measure it. Calibration and Certification Flow Dew Point Oil Vapor Calibration Calibration Calibration Instrument: S401 Serial number: 1234 5768 Item number: S695 8371 Test conditions: Test medium Air Ambient temperature: 18...26°C Test temperature: 23ºC Ambient humidity: 30...60% rH Test humidity: <30 %rH Ambient pressure: 990…1050 mbar Test pressure: 6 bar Calibration range: High speed Testing tube Di: 53.1 mm Testing method: Calibration by comparison References used: Type Model Uncertainty S/N Last Calibration Turbine Flow Meter FT-32 ± 0.50% 141119E39096 10.2021 Laminar Flow Elements LFE0 LFE1 ± 0.50% ± 0.50% 1836000032 1802000011 10.2021 10.2021 Sonic Nozzels N0-N4 ± 0.50% 831K033-37 10.2021 Calibration test results: Description Units Nominal value Permissible uncertainty Actual value Evaluation Flow m3/h 142.2 ±(1.5 % + 0.3% FS) 143.1 passed Flow m3/h 285.4 ±(1.5 % + 0.3% FS) 286.1 passed Flow m3/h 611.2 ±(1.5 % + 0.3% FS) 611.2 passed The above-mentioned calibration was performed according to SUTO iTEC working standards. Furthermore the calibration was performed by comparison with instruments, which have been calibrated at an ISO 17025 accredited calibration laboratory and is traceable to national standards. It represents the physical units according to the International System of units (SI). The reference measurement system used for this calibration has a total uncertainty of 0.65% (at confidence level: 95%) We commend that this measuring instrument should be calibrated annually. The product has been calibrated by: SUTO iTEC GmbH Grißheimer Weg 21 79423 Heitersheim Tel: +49 (0) 7634 50488-00 Fax: +49 (0) 7634 50488-19 E-mail: sales@suto-itec.com Web: www.suto-itec.com Calibration date: 28.09.2022 SUTO Inspector: F. Gleissner Signature: Page 1 of 2 Calibration certificate SUTO Calibration • SUTO iTEC owns high tech calibration facilities in Germany, Hong Kong SAR and Mainland China • Flow calibration under pressure and a wide range for highest accuracy • Real gas calibration system for technical gases • References and certificates are traceable to national standards Exchange Calibration Service Current Meter, other Sensors and Calibration Service Other Sensors Power Meter S110 Stationary S010 Pressure S110-P Portable S020 S030 Temperature Electrical Current Application The main application is to measure the power consumption and the accumulated energy consumption of electrical 3-phase consumers, like compressors, driers and oxygen/nitrogen generators. Application Industrial equipment for manifold applications • Hydraulic and pneumatic systems • Industrial engines • HVAC/R equipment • Spraying systems • Cooling systems Installation DIN rail installation for power cabinets or portable version with rugged housing Installation Easy installation in compressed air systems (for more information visit www.suto-itec.com) Signal Outputs • Isolated 4 ... 20 mA (Analog) • Modbus/RTU Signal Outputs • S010: 4 ... 20 mA • S011: Modbus/RTU • S020: 4 ... 20 mA (available in 2 sizes) • S030: 4 ... 20 mA The exchange calibration service eliminates down time and enables users to have a seamless record of their measurements. The user receives in advance a calibrated instrument with calibration certificate and the same instrument settings. The on-site instrument is then switched against the calibrated one and returned to the supplier. Compressor Rogowski Coils Generation Modbus / RTU Interface can connect to any Modbus-Master 4 ... 20 mA output connection User-friendly design and setup Cost-efficient affordable sensor solutions Multi-functional: 3-phase, 1-phase Industrial design for various applications Various Calibrations: Flow / Dew Point / Oil Vapor / Particle / Pressure/ Temperature See info sheet See info sheet See info sheet Identifying compressor efficiency Strong Protection IP65 Casing See info sheet See info sheet S010 S020 S030

RkJQdWJsaXNoZXIy MjgzNzA=