5/6 Technical Data S601 Stationary Compressed Air Purity Monitor Measurement Particle concentration Accuracy Counting Efficiency according ISO 21501-4 Option A1263: 30 ... 70 % of d > 0.1 μm 90 ... 110 % of d ≥ 0.3 μm Option A1260: 50 % @ 0.1 < d ≤ 0.15 μm 100 % @ d > 0.15 μm Selectable units cn/m³, cn/ft³ Measuring range Option A1263: 0.1 < d ≤ 0.5 μm 0.5 < d ≤ 1.0 μm 1.0 < d ≤ 5.0 μm 5.0 μm < d Option A1260: 0.3 < d ≤ 0.5 μm 0.5 < d ≤ 1.0 μm 1.0 < d ≤ 5.0 μm 5.0 μm < d Sensor Laser optical particle counter Sampling rate 1 min. Flow rate 2.83 l/min Pressure Dew Point Accuracy ± 1 °C Td (0 ... 20 °C Td) ± 2 °C Td (-70 ... 0 °C Td) ± 3 °C (-100 ... -70 °C Td) Selectable units °C, °F Measuring range -100 ... +20 °C Td Sensor QCM + Polymer Response time (t90) -20 °C Td -> -60 °C Td = < 240 sec -60 °C Td -> -20 °C Td = < 30 sec @ 4 l/min Oil vapor Accuracy 5 % of value +/- 0.003 mg/m³ Detection limit 0.001 mg/m³ Resolution 0.001 mg/m³ Selectable units mg/m³ Measuring range 0.001 ... 5.000 mg/m³ Sensor PID (Photoionisation detector) UV lamp lifetime 1 year or 6000 working hours, whichever comes first Sampling rate 1 sec. Pressure Accuracy 0.5 % FS Measuring range 0.1 ... 1.6 MPa(g) Sensor Piezo resistive sensor Temperature Accuracy ± 0.3 °C Measuring range -30 ... +70 °C Sensor Pt100 Reference conditions ISO1217 20 °C / 1000 hPa General data Configuration Others Device comes pre-configured Configuration can be done via on-screen touch Display Integrated Touchscreen, Size: 5“, Resolution: 800 x 480 px Data Logger Storage Up to 3 million recorded data sets (10 channels each) Material Process connection Brass nickel-plated, FKM Housing Sheet steel, powder coated cabinet Miscellaneous Electrical connection AC Clamp Terminals, M12, RJ45 Protection class IP55 (cover lid closed) Approvals CE Process connection Micro quick connector, full pass-through, male (1.5 m hose with coupling included) Weight 15 kg Operating conditions Medium Compressed Air, Nitrogen N₂, Carbon dioxide CO₂ (software setting) Medium quality ISO 8573-1: 4.4.4 or better Medium temperature 0 ... + 40 °C Medium humidity Medium humidity < 40 % rH, no condensation Operating pressure 0.3 ... 1.5 MPa(g) Ambient temperature 0 ... +50 °C Ambient humidity 0 ... 90 % rH Storage temperature -10 ... +70 °C Transport temperature -10 ... +70 °C Signal / Interface & Supply Fieldbus Protocol Modbus/TCP Update rate 1 / sec. Alarm output Relay 2 x Changeover Relay (freely programmable) Rating 230 VAC, 3A Power Supply Voltage supply 100 ... 240 VAC, 50/60 Hz Current consumption 50 VA Interface USB USB Micro with OTG support
RkJQdWJsaXNoZXIy MjgzNzA=