S606 Stationary Breathing Air Quality Analyzer 4/6 Relevant standards including BS EN 12021, DEF STAN 68-284, OSHA, CSA and BS 8478 require adherence to specific limits of constituents in breathing air. Here some examples of the required for industrial breathing air: Why is breathing air quality testing and monitoring important? Dimensions Relevant standards for breathing air It protects the health, safety and well-being of your employees and people who are on your premises. It ensures that your compressor, products and personnel are protected from airborne volatile organic compounds (VOCs) as well It ensures that your business complies with national and international regulatory standards for breathing air quality. It ensures that your compressed air and work environment have safe levels of oxygen, lubricants, oil, odor, taste, carbon dioxide, carbon monoxide and water. 600 mm 600 mm 250 mm Contaminant Europe China USA Canada Standard EN 12021 GB/T 31975-2015 CFR CSA O2 20 - 22 % 19.5 - 23.5 % 19.5 - 23.5 % 20 – 22 % CO2 500 ppm ≤ 1000 mL/m³ 1,000 ppm 500 ml/m3 CO 5 ppm ≤ 10 mL/m³ 10 ppm 5 ml/m3 H2O PDP: < -11 °C 1) H2O: <35 mg/m3 2) H2O: <25 mg/m3 ADP: ≤ -45.6 °C --- --- VOC (Oil Vapor) 0.5 mg/m3 ≤ 5.0 mg/m³ (Oil mist and particle) 5 mg/m3 1 mg/m3 Odor No No No No