קטלוג מוצרים ULPA - SUTO

S606 Stationary Breathing Air Quality Analyzer 5/6 Technical Data General data Configuration Others Device comes pre-configured Configuration can be done via on-screen touch Display Integrated 5” color touch screen Data Logger Storage Up to 3 million recorded data sets Report Integrated report generator for PDF export Material Process connection 6 mm quick connector Housing Sheet steel, powder-coated on the outside (Stainless steel on request) Miscellaneous Electrical connection M12, PG plug, RJ45 Protection class IP55 Water Inlet G1 connector Water Outlet G1/8 connector Dimensions 600 x 600 x 250 mm Weight 34 kg Approvals EMC FCC, CE Operating conditions Measuring Medium Compressed breathing air Sample Flow Rate 6 LPM@4 MPa(g), depends on input pressure Sample rate 1 sample/sec Medium temperature 0 ... +45 °C Medium humidity Medium humidity < 40 % rH, no condensation Inlet Pressure 0.4 ... 1.5 MPa(g), External pressure reducer allow up to 35 MPa process pressure Ambient temperature 0 ... + 50 °C Ambient humidity 0 ... 90 % rH Storage temperature -10 ... +50 °C Transport temperature -10 ... +50 °C Signal / Interface & Supply Fieldbus Protocol Modbus/RTU (RS485) Modbus/TCP (Ethernet) Power supply Voltage supply 100 ... 240 VAC, 50/60 Hz, 50 VA Interface USB USB Micro with OTG support M12 4G/LTE Modem Measurement Oxygen O2 Accuracy ± 1 % of reading ± 0.05 % Measuring range 0 ... 25 % Resolution 0.1 % Sensor Optical oxygen sensor Sensor lifetime > 5 years Carbon Dioxide CO2 Accuracy ± 1 % of reading ± 25 ppm Measuring range 0 ... 1000 ppm Resolution 1 ppm Sensor NDIR sensor Sensor lifetime > 5 years Carbon Monoxide CO Accuracy ± 5 % of reading ± 1 ppm Measuring range 0 ... 20 ppm Resolution 0.1 ppm Sensor Electrochemical sensor Sensor lifetime 2 years Humidity H2O Accuracy ± 1 °C Td (0 ... 20 °C Td) ± 2 °C Td (-70 ... 0 °C Td) ± 3 °C Td (-100 ... -70 °C Td) Measuring range -100 ... +20 °C Td / 0 ... 17458.6 mg/m³ Resolution 0.1 °C Td Sensor QCM + Polymer Sensor lifetime > 10 years Oil Vapor (only for P560 0606) Accuracy 5 % of reading ± 0.003 mg/m³ Measuring range 0.001 ... 5.000 mg/m³ (Based on 1000 hPa(a), 20 °C, 0 % relative humidity) Resolution 0.001 mg/m³ Sensor Photo ionization detector UV lamp lifetime 6,000 working hours or 1 year, whichever comes first Oil Mist and Particle (only for P560 1606) Accuracy 15 % of reading ± 0.1 mg/m³ Measuring range 0.0 ... 5.0 mg/m³ (Based on 1000 hPa(a), 20 °C, 0 % relative humidity) Resolution 0.1 mg/m³ Sensor Oil mist and particle sensor Sensor lifetime > 5 years Pressure Accuracy 0.5 % FS Measuring range 0 ... 16 bar(g) Resolution 0.01 bar Sensor Piezo resistive pressure sensor

RkJQdWJsaXNoZXIy MjgzNzA=