Ordering Please use the following table to assist in placing your order with our sales staff. Exchange Service No Downtime anymore! The exchange calibration service eliminates down time and enables users to have a seamless record of their dew point measurements. The user receives in advance a calibrated instrument with calibration certificate and the same instrument settings. The on-site instrument is then switched against the calibrated one and returned to the supplier. www.suto-itec.com sales@suto-itec.com Calibration and Certification International Edition (EN) - 24-1. © 2024 SUTO iTEC GmbH. www.suto-itec.com Calibration and Certification Order No. Description Send-in calibrations - Adjustment with outgoing calibration (As left) R200 0001 Flow Meter (Air/Gas) - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0020 Flow Meter (Gas) - Adjustment with outgoing calibration (As left), Calibration in Real Gas: O2, Ar, CO2, H2 (for H2 please contact manufacturer in advance) R200 0021 Flow Meter (Gas) - Adjustment with outgoing calibration (As left), Calibration in Real Gas: CH4, Natural Gas, N2O R200 0022 Flow Meter (Gas) - Adjustment with outgoing calibration (As left), Calibration in Real Gas: Helium R200 0030 Pressure Transmitter (0… 1.6 MPa) - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0040 Re-calibration ultrasonic flow meter S460 R200 0060 O2 Sensor- Adjustment with outgoing calibration (As left) with Service: General inspection of the unit R200 0061 CO Sensor- Adjustment with outgoing calibration (As left) with Service: General inspection of the unit R200 0062 CO2 Sensor- Adjustment with outgoing calibration (As left) with Service: General inspection of the unit R200 0063 Oil mist and particle sensor - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0070 Leak Detector S531 - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0080 Power Meter S110 - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0090 Rogowski Coil - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components R200 0120 Oil Vapor sensor - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components - UV lamp replacement - General inspection of the unit - Cleaning of components - UV lamp replacement R200 0121 Oil Vapor sensor with Dew point sensor option - Adjustment with outgoing calibration (As left) with Service: - General inspection of the unit - Cleaning of components - UV lamp replacement
RkJQdWJsaXNoZXIy MjgzNzA=