www.suto-itec.com S600 TECHNICAL DATA General Specifications Measuring unit 5” colour touchscreen with data logger, guided measurement and report generator function. All combined and integrated with the multiple sensor system. Process connection Micro quick connector, full passthrough, male (1.5 m hose with coupling included) Operating pressure 0.3 ... 1.5 MPa Ambient temperature 0 ... +50 °C Storage & Transport temperature -10 ... + 70 °C Medium Compressed Air, Nitrogen N2, Carbon dioxide CO2 (software setting) Medium temperature 0 ... + 40 °C Medium humidity < 40 % rH, no condensation Reference settings ISO1217 20 °C 1000 mbar UV lamp lifetime (oil vapor sensor) 1 year or 6000 working hours, whichever comes first Power supply Mains supply adapter (AC/DC) Input: 100 ... 240 VAC, 50/60 Hz, 1.4 A Output: 24 VDC, 2.5 A, 60 W max. Data logger 100 mio. values, Integrated report generator for PDF export Measured values Temperature, Pressure, Oil vapor, Dew point, Particle concentration Interface USB, Ethernet (Modbus/TCP) Display Touchscreen, Size: 5“, Resolution: 800 x 480 px Dew point sensor Dual-sensor technology (QCM & Polymer) Particle sensor Laser optical detection Oil vapor sensor PID (Photoionisation detector) Measurement duration min. 35 minutes (no upper limit) Sampling rate 1 sample / sec. Classification IP65 (cover lid closed) Casing material PC + ABS, Al alloy Weight 9.8 kg EMC IEC 61326-1 Measurement Specifications Measurement range Particle counter 0.1 < d ≤ 0.5 μm ; 0.5 < d ≤ 1.0 μm ; 1.0 < d ≤ 5.0 μm Measurement range Dew point sensor -100 ... +20 °C Td Measurement range Oil vapor sensor 0.003 ... 10.000 mg/m3 Detection limit oil vapor sensor 0.003 mg/m3 Resolution oil vapor sensor 0.001 mg/m3 Accuracy Particle measurement 50 % @ 0.1 < d ≤ 0.15 μm 100 % @ 0.15 μm > d per JIS Accuracy Dew point measurement ±2 °C Td Accuracy Oil vapor measurement 5 % of value ± 0.003 mg/m3 General Specifications Isokinetic sampling device Measuring unit Sampling pipe with integrated isokinetic sampling tube, flow regulation and control by integrated flow sensor, to be used for particle measurements according to ISO8573 Process connection Micro quick connector, full passthrough, male (1.5 m hose with coupling and connection hoses to S600 included) Operating pressure 0.3 ... 1.5 MPa Ambient temperature 0 ... +50 °C Storage & Transport temperature -10 ... +70 °C Flow sensor Thermal mass flow, only for isokinetic flow setup, no system-flow measurement Interface Communication interface for S600, cable included, M8 Accuracy 3 % o. RDG Purge flow Regulated by needle valve, setup guided by S600
RkJQdWJsaXNoZXIy MjgzNzA=