www.suto-itec.com sales@suto-itec.com International Edition (EN) - 23-1. © 2023 SUTO iTEC GmbH. www.suto-itec.com S217 OEM Compact Dew Point Transmitter Technical Data General Specifications Measurement range (model depending) Dew point Temperature -60 ... +20 °C Td -20 ... +50 °C Td -30 ... +70 °C Dew point sensor Polymer Temperature sensor NTC Pressure sensor N/A Accuracy Dew point Temperature ±2 °C Td 0.3 °C Operating Pressure -0.1 ... 5.0 MPa Operating Temperature (Medium) -30 ... +70 °C Measured gases (Medium) Non-corrosive gases Response Time t90 (@ 4 l/min) -40 °C Td -> -20 °C Td = 20 sec 0 °C Td -> -40 °C Td = 120 sec Ambient Temperature -20 ... +50 °C Ambient Humidity 0 ... 100 %rH Supply Voltage 12 ... 30 VDC Current consumption (model depending) 30 mA @ 24 VDC 3-Wire, Modbus/RTU 20 mA @ 24 VDC 2-Wire Output signals (model depending) 4 ... 20 mA 3-Wire 4 ... 20 mA 2-Wire Modbus/RTU IO-Link (please inquire) Electrical connection Cable, 1.8 m, open end wire, M8 connector, 4 poles Process connection G 1/2“ thread (ISO 228/1) Stainless steel 1.4301 (SUS 304) Casing material Aluminum alloy Classification IP65 EMC IEC 61326-1 Approval - Sensor protection Sinter filter Transport Temperature -30 ... +70 °C Storage Temperature -20 ... +50 °C Weight 198 g Stated accuracy under following conditions: • Ambient temperature 23 °C ±3 °C • Process temperature 23 °C ±3 °C • Ambient humidity < 95 %, no condensation Please use the following table to assist in placing your order with our sales staff. S217 OEM Compact Dew Point Transmitter Order No. Description S699 2176 S217-6, dew point sensor, 4 ... 20 mA (2-wire), -60 ... +20 °C Td, G 1/2” thread, 5.0 MPa, M8 S699 2173 S217-3, dew point sensor, 4 ... 20 mA (2-wire), -20 ... +50 °C Td, G 1/2” thread, 5.0 MPa, M8 S699 2177 S217-7, dew point sensor, 4 ... 20 mA (3-wire), -60 ... +20 °C Td, G 1/2” thread, 5.0 MPa, M8 S699 2174 S217-4, dew point sensor, 4 ... 20 mA (3-wire), -20 ... +50 °C Td, G 1/2” thread, 5.0 MPa, M8 S699 2178 S217-8, dew point sensor, Modbus/RTU, -60 ... +20 °C Td, G1/2” thread, 5.0 MPa, M8 S699 2179 S217-9, dew point sensor, Modbus/RTU, -20 ... +50 °C Td, G1/2” thread, 5.0 MPa, M8 Custom range A1390 S217, customized measuring range (please specify your range and scaling request) High pressure option A1391 S217, high pressure option 35 MPa (350 bar) Accessories A699 3491 Measuring chamber for easy installation in compressed air system up to 15 bar A699 3493 Measuring chamber bypass type (in and out 6 mm hose connection) Ordering

RkJQdWJsaXNoZXIy MjgzNzA=