Dimensions Ø49mm Ø74mm 384mm Inch DN Di (mm) Standard (m3/h) Max (m3/h) 1” DN25 27.3 0.5 ... 147 0.6 ... 294 1¼” DN32 36.0 0.9 ... 266 1.2 ... 531 1½” DN40 41.9 1.2 ... 366 1.5 ... 731 2” DN50 53.1 2.0 ... 600 2.5 ... 1197 2½” DN65 68.9 3.5 ... 1026 5.0 ... 2048 3” DN80 80.9 5.0 ... 1424 7.0 ... 2842 4” DN100 100.0 10 ... 2183 12 ... 4357 5” DN125 125.0 13 ... 3419 18 ... 6824 6” DN150 150.0 18 ... 4930 25 ... 9838 8” DN200 200.0 26 ... 8785 33 ... 17533 10” DN250 250.0 40 ... 13743 52 ... 27428 12” DN300 300.0 60 ... 19814 80 ... 39544 The table shows flow ranges up to 300 mm pipe diameter at standard conditions in air. Other standard conditions and gases flow ranges are available on request. In larger pipe diameters flow can also be measured. Comprehensive Monitoring In a factory setting, several S402 OEM Flow Meters can be connected together with a monitoring system via Modubus/RTU to provide a comprehensive view of the compressed air usage and flow. This helps factory managers and operators to identify and address any issues quickly, ultimately improving the overall efficiency of the production process. S402 OEM Thermal Mass Flow Meter Volumetric Flow Ranges 14mm 3/4
RkJQdWJsaXNoZXIy MjgzNzA=